Common Issues Caused by Harmonics

Harmonic Mitigation Solutions

PowerMore designs and deploys solutions for each real-world application

01.System Survey & Measurement
  • Identify key measurement points (PCC, distribution cabinets, major loads)
  • Collect actual operating data of the system
  • Conduct a preliminary assessment of the current condition and abnormal signs
02.Analysis & Root Cause Identification
  • Analyze harmonic data (TDD, THDv, imbalance, resonance)
  • Identify interference sources: inverters, UPS, renewable energy systems, ...
  • Assess the level of impact on equipment and operation
03.Design a Suitable Solution
  • Select the appropriate filtering technology (Active, Passive, or Hybrid) according to the system from medium voltage to low voltage
  • Simulate the system to evaluate effectiveness before deployment
  • Optimize between technical effectiveness, investment cost, and equipment durability
04.System Deployment & Acceptance
  • Install and configure according to actual operating conditions
  • Coordinate with the operation team to ensure stable system operation
  • Inspect and accept according to relevant standards
05.Long-Term Monitoring & Optimization
  • Monitor effectiveness after being put into operation
  • Adjust to maintain stable efficiency over time
  • Support plant engineers in maintenance and troubleshooting when needed

Ba Na Hills Resort | Deployment of Comsys ADF Active Harmonic Filter

PowerMore surveyed and assessed the harmonic conditions in the cable car system at Ba Na Hills and deployed the ADF – Comsys harmonic filter system. The solution helps address current and voltage distortion, while improving power factor and enhancing operational stability for the system at Station 6 – Ba Na Hills.

Ba Na Hills Resort | Deployment of Comsys ADF Active Harmonic Filter
Ba Na Hills Resort | Deployment of Comsys ADF Active Harmonic Filter
PowerMore surveyed and assessed the harmonic conditions in the cable car system at Ba Na Hills and deployed the ADF – Comsys harmonic filter system. The solution helps address current and voltage distortion, while improving power factor and enhancing operational stability for the system at Station 6 – Ba Na Hills.
View more
Hoa Phat Dung Quat | Deployment of 35kV Medium-Voltage Harmonic Filter System
Hoa Phat Dung Quat | Deployment of 35kV Medium-Voltage Harmonic Filter System
In response to urgent requirements for power quality and operational safety, PowerMore deployed a 35kV medium-voltage harmonic filter system to eliminate harmonics directly at the source. The solution was designed with a high-pass harmonic filter configuration for the 5th, 11th, and 23rd harmonic orders.
View more
CTR Vina | Deployment of Active Harmonic Filter for Variable Frequency Drive System
CTR Vina | Deployment of Active Harmonic Filter for Variable Frequency Drive System
With experience in the field of power quality, PowerMore deployed a hybrid harmonic mitigation solution, combining the advantages of passive filtering and active filtering. This solution helps reduce harmonics in the electrical system while supporting more stable system operation.
View more
ICT Vina | Deployment of Revcon RHF Active 100A Active Harmonic Filter
ICT Vina | Deployment of Revcon RHF Active 100A Active Harmonic Filter
Deployment of the Revcon RHF Active 100A active harmonic filter at locations where THDi was >12% due to variable frequency drives, helping reduce THDi to below 5%, in compliance with IEEE 519 and the requirements of Circular 05/2025/TT-BCT.
View more
Vinamilk | Deployment of 12 Active Harmonic Filters (AHF) with a Total Capacity of 1,800A
Vinamilk | Deployment of 12 Active Harmonic Filters (AHF) with a Total Capacity of 1,800A
The project also demonstrates that harmonic control is not merely a standalone technical requirement, but part of a sustainable operation strategy in the F&B industry. For factories with high operating intensity, large nonlinear loads, and strict requirements for operational continuity, power quality is a fundamental condition for maintaining production efficiency.
View more